We use cookies to provide you with a better experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie Policy.

logo
  • Engineers & Specifiers
  • Contractors & Installers
  • Wholesalers & Distributors
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Free Subscription
  • Sign In
  • Create Account
  • Sign Out
  • My Account
  • PRODUCTS
    • Bath & Kitchen
    • Fire Protection
    • HVAC
    • Hydronics/Radiant
    • Plumbing
    • PVF
    • Tools
  • PROJECTS
    • Commercial
    • Green Building
    • MRO/Retrofit
    • Remodeling
    • Residential
  • HOW TO
    • Design
    • Fire Protection
    • Legal Matters
    • Management
  • BUSINESS
    • Buying Groups
    • Technology
    • Associations
  • CODES & STANDARDS
    • ANSI
    • ASHRAE
    • ASSE
    • Regulations
    • Green Building
    • IAPMO
    • ICC
    • NFPA
  • RESOURCES
    • Media Kit
    • Advertise
    • Contact Us
    • Classifieds
    • Digital Editions
    • Behind the Wall
    • Webinars
    • AHR Live 2023
  • PODCASTS
  • DIGITAL EDITIONS
Home » Hot Water Recirculation in High-Rise Buildings

Hot Water Recirculation in High-Rise Buildings

March 15, 2014
No Comments

Pumping systems are contributing significantly to the success of this trend through the use of alternative applications including variable frequency drives, water heaters with minimal or no storage, and innovations such as incorporating expansion tanks and jockey pumps in pressure booster systems to maximize off-peak performance.

Hot water recirculation pumps are being applied to systems in order to decrease the unnecessary “dumping” of cold water, and the resulting convenience coupled with water savings, both offer significant benefits to the user. Such recirculation pumps typically have fractional horsepower motors and run constantly. In a typical 2- 3-story hospital or school building, recirculation works well because the circulators only have to overcome friction losses in the piping and function simply as closed loop pumps.

However, in a high-rise building, the issue is more complicated. A typical 26-story high rise building may have three recirculation pumps and hot water heaters at the top of the building in a down-feed style supply. Water is boosted from the basement to the top of the building, and in the illustration shown in Figure 2, pressure of 38 psi must be maintained at the top.

This forces the water through PRVs in each lower zone in order to avoid excessive pressures at the fixtures. The pump must act not only as a recirculation pump but also as a pressure booster. Pump P3 in Figure 1 would be sized around 15 GPM @ 210 FT to overcome friction losses and the static height of the building, and it must be capable of pumping potable water but the standard 175 psi seals become marginal and pump efficiency at this low flow is poor at best.

One way to separate the negative effects of the PRVs is to ‘decouple’ the recirculation loop, and this can be done with brazed plate heat exchangers, which provide a cost effective solution to the issue. We can save operating horsepower by using a low-head (pressure) pump instead of a high-head pump. The initial cost of a small single-wall brazed plate heat exchanger and the low-head pump is comparable to the cost of a high-head pump. Each isolated group does need its own tank, isolation and balancing valves, but the balancing act is simplified since we don’t have to try to balance multiple high-pressure pumps on various floors with each other. We can even run the secondary zones with aquastats. The net effect is a more efficient and quieter running plumbing system.

To illustrate a more efficient and quieter running plumbing system, see the drawings, left, above. One shows the traditional method of piping a domestic hot water recirculation system, and the other shows an alternate system using a “decoupled” approach. De-coupled recirculation offers significant benefits and should be considered for greener high-rise building applications.

Information for this article was provided by ITT/Bell & Gossett.

Engineers & Specifiers Hydronics/Radiant
  • Related Articles

    AquaMotion Awarded U.S. Patent for AMK-ODR Hot Water Recirculation Valve

    Weil-McLain Advanced AquaBalance High Efficiency Combi-Boiler Brings Heat and Hot Water into Balance

    Internal Recirculation System

You must login or register in order to post a comment.

Report Abusive Comment

Most Popular

  • SLB Announces Newmans Valve as NEWCO Valve Supplier for Western Hemisphere

  • Duravit Announces New Hires and Promotions

  • PVF Roundtable Annual Golf Tournament Registration Now Open

  • Chicago Plumber’s Union Dyes Chicago River Green for St. Patrick’s Day 2023

Featured Video

Caleffi video thumb

The Gold Standard: Separation with NO Compromise

Industry Events

  • 11Apr

    ASA ELEVATE2023

    Charleston, SC
  • 18Apr

    2023 WQA Convention & Exposition

    Las Vegas, NV
  • 18Apr

    2023 AD Decorative Brands Annual Meeting

    Boston, MA
More Events

Subscribe to our newsletters & stay updated

Subscribe & Learn More

  • Tw03 2023 cover
    Learn More
  • Pe03 2023 cover
    Learn More
  • Phc03 2023 cover
    Learn More
  • Es 2022
    Learn More
Subscribe

More from PHCP Pros

  • Editorial Team
  • Home
  • Contact Us
  • About
  • Advertise

Follow Us

© 2023 All Rights Reserved

Design, CMS, Hosting & Web Development | ePublishing